Home / Products / Engineered Specialty Mortars / High-Strength Non-Shrink Grout

High-Strength Non-Shrink Grout CGM-C60 · Class III

Complies with GB/T 50448-2015; measured 28-day compressive strength of 75.7 MPa. Suited to equipment base secondary grouting, anchor bolt anchoring and structural strengthening.

High-Strength Non-Shrink Grout packaging

High-Strength Non-Shrink Grout

Standard: GB/T 50448-2015

A factory-blended dry powder of high-strength aggregate, cement and multiple functional admixtures. Once mixed with water it delivers high flowability, slight expansion, and rapid early-and-high strength. It fills completely and bonds strongly with steel reinforcement, and is widely used for equipment base secondary grouting, bridge bearing grouting, anchor bolt anchoring and concrete structural strengthening and repair.

28d strength 75.7 MPa High flow · no vibration Slight expansion 1d early strength 29.9 MPa Test reports shipped with every batch
LAB TESTED

Third-Party Tested · Measured Data

Tested by Hunan Provincial Institute of Product and Commodity Quality Inspection · Report No. J2026-02-W014435 · All items passed

Test ItemUnitRequirementResultVerdict
Flow (cone) · initialmm≥290328Pass
Flow (cone) · 30 minmm≥260310Pass
Compressive strength · 1dMPa≥2029.9Pass
Compressive strength · 3dMPa≥4056.7Pass
Compressive strength · 28dMPa≥6075.7Pass
Vertical expansion · 3h%0.1–3.50.751Pass
Expansion diff (24h−3h)%0.02–0.500.067Pass
Bleeding rate%00Pass
Chloride ion content%<0.10.031Pass

Test methods: GB/T 50448-2015, GB/T 50080-2016, GB/T 8077-2023. Data extracted from the test report (J2026-02-W014435) issued by Hunan Provincial Institute of Product and Commodity Quality Inspection. Sample: High-Strength Non-Shrink Grout, model CGM-C60 Class III.

+26% Measured 28-day compressive strength of 75.7 MPa, exceeding the ≥60 MPa requirement by 26% — not satisfied with merely "passing", we pursue margin of safety.
328mm

Initial cone flow, well above the ≥290 mm requirement. Self-leveling, no vibration, pumps cleanly over long distances.

29.9MPa · 1d

Nearly 30 MPa in one day — rapid early strength that shortens equipment installation and hoisting wait time.

0bleeding

Zero bleeding — the grout layer does not stratify or exude water, guaranteeing density.

MA
CNAS
Traceable Reports · Authoritative Laboratory

Hunan Provincial Institute of Product and Commodity Quality Inspection (MA No. 221800110834 · CNAS L9526 · ilac-MRA mutual recognition). Commissioned testing with the official inspection seal; full documentation accompanies every shipped batch.

Report No.: J2026-02-W014435
Model: CGM-C60 Class III
TEST REPORTS

Test Report Archive

2025–2026 commissioned tests, all issued by Hunan Provincial Institute of Product and Commodity Quality Inspection · click a cover to view the original

Grout test report data page

A Report You Can Actually Read

A test report isn't just "there" — we publish every measured value online, inviting engineers and supervisors to compare and verify.

  • Requirements and measured results listed item by item — verifiable, recalculable
  • Reports carry MA / CNAS marks and the official inspection seal
  • Every batch ships with its test report and certificate of conformity
  • Special requirements can be arranged via additional commissioned tests, with on-site sampling support
Request the Full Test Report →