Home / Products / Engineered Specialty Mortars / Tunnel Secondary Lining Grout

Tunnel Secondary Lining Grout T/CECS 1049-2022

Dedicated backfill grout behind tunnel secondary lining; good injectability, slight expansion and firm bond to eliminate voids.

Tunnel Secondary Lining Grout packaging

Tunnel Secondary Lining Grout

Standard: T/CECS 1049-2022

A purpose-designed grout for backfilling behind tunnel secondary lining. It offers high flowability, good injectability, slight expansion, firm bonding with surrounding rock and lining, plus durability and impermeability — effectively filling voids and under-compacted zones behind the lining to improve the tunnel's structural integrity and waterproofing.

Good injectabilitySlight expansionFirm bondDurable · impermeableDense · non-shrink
KEY FEATURES

Product Features

01

Good injectability

Excellent flow and injectability to reach narrow gaps and voids behind the lining.

02

Slight expansion

Moderate expansion gives fuller filling and tight contact with rock and lining.

03

Firm bond

Strong adhesion to existing concrete and surrounding rock for a monolithic load path.

04

Durable & impermeable

Impermeable and durable, sealing water paths and improving tunnel waterproofing.

05

Dense & stable

Non-shrinking, non-stratifying — the grout body stays dense and reliable over time.

06

Wide adaptability

Works with low- or high-pressure injection equipment across varied geological conditions.

Technical Parameters

FormSingle-component dry powder (add water and mix)
StandardT/CECS 1049-2022
ApplicationBackfill behind secondary lining, voids behind primary support, shield tail grouting
PackingBagged, subject to factory packaging
QCEvery batch tested; test reports and certificates shipped with goods

Applications

  • Backfill grouting behind tunnel secondary lining
  • Void and delamination filling behind primary support
  • Shield tunnel tail-void grouting
  • Rock reinforcement and water-stop sealing in underground works
APPLICATION

Construction Steps

General application steps; refer to the technical brief for specifics

1

Drill

Lay out and drill grout holes on the lining to the designed depth.

2

Clean

Clear debris and water from holes, blow clean with high-pressure air if needed.

3

Mix

Mix to the specified water ratio until uniform, then sieve before use.

4

Inject

Inject from low to high pressure in stages, watching pressure and intake.

5

Seal & check

Seal the hole once full; after initial set, check density and re-grout if needed.

MA
CNAS
Batch-Tested · Traceable Quality

All products are produced to national / industry standards and tested by third-party laboratories. Reports carry MA / CNAS marks and the official inspection seal, and accompany every shipped batch with the certificate of conformity.

RELATED

Related Products

Click a product to view its detail page